300403

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 drive software and drive MD with different version numbers

%1 = NC axis number %2 = Drive number

The version number of the drive software (FDD/MSD) must correspond to the version number stored in the drive machine data because the MD files for different software versions are not compatible.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. After exchanging the drive software, the drives must be installed and started up again. Any MD files that were saved by the control running under the old version must no longer be used. The old data can be saved with the installation and start-up tool and this data can also be used again.

Clear alarm with the RESET key in all channels. Restart part program.


© Siemens AG 2005 All Rights Reserved


1-2542