300400

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 system error, error codes %3, %4

%1 = NC axis number %2 = Drive number %3 = Error code 1 %4 = Error code 2

An internal software error or serious error condition has occurred which may be recoverable by hardware reset. Troubleshooting can generally be performed only by Siemens AG, System Support for A&D MC Products, Hotline (tel.: see alarm 1000).

In the error code combination (324,26), the calculation time allocation for the drive communication subtask should be increased via the MD 10140 $MN_TIME_LIMIT_NETTO_DRIVE_TASK (possible up to 500 ms).

If the above-mentioned limit is exhausted and the alarm continues to occur, the MD 10150 $MN_PREP_DRIVE_TASK_CYCLE_RATIO=1 can be set additionally. Please note that by reducing MD 10150, the time share of the preparation in the non-cyclic time plane is reduced. This may lead to longer block cycle times.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. You can try to power the system up again. The search for the precise cause of error can only be performed by the development team. The displayed error codes are always needed for this.

(contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.: see alarm 1000).

Switch control OFF - ON.


1-2539