300201

Axis %1 drive %2 timeout during access, error location %3

Parameters:

%1 = NC axis number

%2 = Drive number %3 = Error location

Definitions:

The read cycle of a drive address in the initialization phase or in cyclic operation has not ended within the monitoring time (approx. 1 ms) (timeout error).

The error can occur in conjunction with a power failure of one or several drive modules. A hardware fault might also be the cause (ASICs, bus, drive modules).

Reactions:

-    NC not ready.

-    The NC switches to follow-up mode.

-    Mode group not ready, also effective for single axes

-    NC Start disable in this channel.

-    Axes of this channel must be re-referenced.

Remedy:

-    Interface signals are set.

-    Alarm display.

Please inform the authorized personnel/service department. If the alarm has occurred in conjunction with a power failure, this cause of failure must be eliminated. Otherwise, please contact the system support for A&D MC products, SIEMENS AG, through the Hotline (tel.: see alarm 1000).

Program Continuation:

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved