111420

Definitions:

Reactions:

Remedy:


Program Continuation:


Error during the inch/metric conversion! Check all data!

The switchover of the data for the inch/metric conversion was not completed. This alarm can only appear in the event of hardware defects.

-    NC Start disable in this channel.

-    Alarm display.

The following data must be checked:

Display MD's:

MD9004: $MM_DISPLAY_RESOLUTION

MD9600: $MM_CTM_SIMULATION_DEF_X

MD9601: $MM_CTM_SIMULATION_DEF_Y

MD9602: $MM_CTM_SIMULATION_DEF_VIS_AREA

MD9603: $MM_CTM_SIMULATION_MAX_X

MD9604: $MM_CTM_SIMULATION_MAX_Z

MD9605: $MM_CTM_SIMULATION_MAX_VIS_AREA

MD9616: $MM_CTM_TEACH_HANDW_FEED_P_MIN

MD9617: $MM_CTM_TEACH_HANDW_FEED_P_REV

MD9620: $MM_CTM_CYCLE_SAFETY_CLEARANCE

MD9633: $MM_CTM_INC_DEC_FEED_PER_MIN

MD9634: $MM_CTM_INC_DEC_FEED_PER_ROT

MD9637: $MM_CTM_MAX_INP_FEED_P_MIN

MD9638: $MM_CTM_MAX_INP_FEED_P_ROT

MD9639: $MM_CTM_MAX_TOOL_WEAR

MD9648: $MM_CTM_ROUGH_O_RELEASE_DIST

MD9649: $MM_CTM_ROUGH_I_RELEASE_DIST

MD10240: $MN_SCALING_SYSTEM_IS_METRIC

MD20150 [12]: $MC_GCODE_RESET_VALUES

Tool data: Length X, length Z, wear length radius X and Z, vconst.

Zero offsets: Position in X, Z.

Internal


1-2347