Program Continuation:
Error during the inch/metric conversion! Check all data!
The switchover of the data for the inch/metric conversion was not completed. This alarm can only appear in the event of hardware defects.
- NC Start disable in this channel.
- Alarm display.
The following data must be checked:
Display MD's:
MD9004: $MM_DISPLAY_RESOLUTION
MD9600: $MM_CTM_SIMULATION_DEF_X
MD9601: $MM_CTM_SIMULATION_DEF_Y
MD9602: $MM_CTM_SIMULATION_DEF_VIS_AREA
MD9603: $MM_CTM_SIMULATION_MAX_X
MD9604: $MM_CTM_SIMULATION_MAX_Z
MD9605: $MM_CTM_SIMULATION_MAX_VIS_AREA
MD9616: $MM_CTM_TEACH_HANDW_FEED_P_MIN
MD9617: $MM_CTM_TEACH_HANDW_FEED_P_REV
MD9620: $MM_CTM_CYCLE_SAFETY_CLEARANCE
MD9633: $MM_CTM_INC_DEC_FEED_PER_MIN
MD9634: $MM_CTM_INC_DEC_FEED_PER_ROT
MD9637: $MM_CTM_MAX_INP_FEED_P_MIN
MD9638: $MM_CTM_MAX_INP_FEED_P_ROT
MD9639: $MM_CTM_MAX_TOOL_WEAR
MD9648: $MM_CTM_ROUGH_O_RELEASE_DIST
MD9649: $MM_CTM_ROUGH_I_RELEASE_DIST
MD10240: $MN_SCALING_SYSTEM_IS_METRIC
MD20150 [12]: $MC_GCODE_RESET_VALUES
Tool data: Length X, length Z, wear length radius X and Z, vconst.
Zero offsets: Position in X, Z.
Internal