111107

Definitions:

Reactions:

Remedy:

Program Continuation:

Reference mark not found

When referencing, the spindle turned through a greater distance than given in the axis-specific machine data 34,060 REFP_MAX_MARKER_DIST, without receiving a reference mark signal. The check is performed for spindle positioning with SPOS or SPOSA when the spindle has not previously run with speed control (S=...).

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Check and correct the MD 34 060 REFP_MAX_MARKER_DIST. The value entered states the distance in [mm] or [degrees] between 2 zero markers.

Clear alarm with the RESET key. Restart part program

1-2322

© Siemens AG 2005 All Rights Reserved