75600

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 RESU: wrong MD configuration. Error code %2

%1 = Channel number %2 = Error code

The following errors were detected in the machine data of the retrace support function when ramping up:

Error code = 4 : Machine date $MC_MM_NUM_CC_BLOCK_ELEMENTS or $MC_MM_NUM_CC_BLOCK_USER_MEM must be increased.

Error code = 5 : Insufficient heap memory for compile cycles available. Adjust machine data $MC_RESU_RING_BUFFER_SIZE, $MC_RESU_SHARE_OF_CC_HEAP_MEM and $MC_MM_NUM_CC_HEAP_MEM.

Error code = 6 : The machine data $MN_ASUP_START_MASK and $MN_ASUP_START_PRIO_LEVEL are not set correctly.

Error code = 11: Machine data $MC_AXCONF_GEOAX_NAME_TAB[n], $MN_INTERMEDIATE_POINT_NAME_TAB[n] and $MN_IPO_PARAM_NAME_TAB[n] are not set correctly for RESU:

Error code = 13: With bit 2 = 0 of MD $MC_RESU_SPECIAL_FEATURE_MASK it was specified that the retraction program cc_resu.mpf is to be stored in the DRAM parts program memory. However, no DRAM parts program memory was requested via MD $MN_MM_DRAM_FILE_MEM_SIZE. Remedy: Either set MD $MN_MM_DRAM_FILE_MEM_SIZE to a value inequal to zero or set bit 2 of MD $MC_RESU_SPECIAL_FEATURE_MASK equal to one.

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Correct machine data.

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved


1-1760