75005

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 block %2 CLC: General programming error

%1 = Channel number %2 = Block number

The activation / deactivation command for the clearance control "CLC(..)" accepts only the values 3, 2, 1, 0 and -1 as call parameters. This alarm signals that parameters are incorrect or missing. The activation command CLC(2) with monitoring of the sensor collision signal is accepted only if a valid digital input is configured for the monitoring signal in MD $MC_CLC_SENSOR_TOUCHED_INPUT.

-    Interpreter stop

-    Alarm display.

Modify part program. Configure the digital input for the collision evaluation in MD if necessary.

Clear alarm with the RESET key. Restart part program


1-1733