61808

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Channel %1 block %2: Final drilling depth or single drilling depth missing

%1 = Channel number %2 = Block number, label

The total depth Z or individual drilling depth Q is missing from theG8xblock (initial cycle call).

-    Interpreter stop

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

Internal


© Siemens AG 2005 All Rights Reserved


1-1604