Channel %1 Block %2: Modify tool tip position
%1 = Channel number %2 = Block number, label
The tool tip is below the measuring probe surface (e.g. for a ring gauge or cube). Alarm is triggered: CYCLE971, CYLCE972, CYCLE982, E_MT_CAL, E_MT_LEN, E_MT_RAD. Place the tool above the measuring probe surface.