Reactions:
Remedy:
Program Continuation:
Channel %1 block %2: Contour violation of grooves
%1 = Channel number %2 = Block number, label
Incorrect parameterization of the milling pattern in the parameters which define the position of the slots/elongated holes on the circle and their form. Alarm triggered by following cycles: SLOT1, SLOT2, LONGHOLE.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Clear alarm with the RESET key. Restart part program
© Siemens AG 2005 All Rights Reserved