61010 |
Channel %1 Block %2: Finishing allowance too large |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
The finishing allowance for the base is greater than the total depth. Alarm triggered by following cycle: CYCLE72. |
Reactions: |
- Alarm display. - Interface signals are set. - NC Start disable in this channel. |
Remedy: Program Continuation: |
- Interpreter stop Reduce finishing allowance. Clear alarm with the RESET key. Restart part program |