28020

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


NCU link: too many link axes configured %1

%1 = Number of link axis connections

Unfortunately, the communication capacity of the NCU link is insufficient for this link axis configuration.

The link axis configuration is determined by the following MDs: $MN_AXCONF_LOGIC_MACHAX_TAB

$MN_AXCT_AXCONF_ASSIGN_TAB1 ... and all further container def.

-    NC not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Connect a smaller number of axes across the link or combine the axes in fewer containers.

Machine data to be changed:

$MN_AXCONF_LOGIC_MACHAX_TAB

$MN_AXCT_AXCONF_ASSIGN_TAB1 ... and all further container def.

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved


1-1280