28011

IPO time insufficient for NCU link. Link cycle time: %1

Parameters:

Definitions:

%1 = Microseconds

Error message of the NCU link module. All messages must be transmitted within one interpolator cycle. This applies particularly to message retries. The time was not sufficient! The parameter indicates how many microseconds the NCU link module needs in order to send the message.

Reactions:

-    NC not ready.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Increase the interpolator cycle time, i.e. modify one of the following MDs on all NCUs. IPO_SYSCLOCK_TIME_RATIO

SYSCLOCK_CYCLE_TIME

Program Continuation:

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved