28007

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


NCU link: conflict in configuration data of NCU %1

%1 = NCU number

Error message of the NCU link module. When the NCU link was powered up, the local NCU (indicated by the alarm) detected a conflict between its configuration and the configuration of the NCU in the alarm parameter.

Example: Machine data LINK_NUM_OF_MODULES defines the number of nodes on the NCU link network. The alarm occurs if this MD has a different setting on different NCUs.

-    NC not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Check machine data configuration.

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved


1-1274