PROFIsafe: Number of NCK F modules (%1) <> Number of S7 F modules (%2)
%1 = Number of parameterized NCK F modules
%2 = Number of parameterized S7 F modules
The number of F modules parameterized via the NCK machine data
$MN_PROFISAFE_IN/OUT_ADDRESS is:
Greater than the number of PROFIBUS slaves in the S7 PROFIBUS configuration. Smaller than the number of F modules in the S7 PROFIBUS configuration, greater than the number of F modules known in the S7 PROFIBUS configuration.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Check the F parameterization in MD $MN_PROFISAFE_IN/OUT_ADDRESS. Check the F configuration in the S7 PROFIBUS configuration.
Check the parameterized PROFIsafe master address in MD $MN_PROFISAFE_MASTER_ADDRESS and in the S7 PROFIBUS configuration. Switch control OFF - ON.