27204

Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


PROFIsafe: double assignment MD %1[%2] - MD %3[%4]

%1 = MD name 1

%2 = MD array index for MD name 1 %3 = MD name 2

%4 = MD array index for MD name 2

A double assignment has illegally been parameterized in the specified machine data:

$A_INSE parameterized on DMP as well as PROFIsafe modules. Involved MDs:

MD $MN_SAFE_IN_HW_ASSIGN MD $MN_PROFISAFE_IN_ASSIGN

$A_INSE parameterized on several PROFIsafe modules. Involved MD:

MD $MN_PROFISAFE_IN_ASSIGN

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Correct the MD.

Switch control OFF - ON.


1-1245