Axis %1 stop B triggered
%1 = Axis number
This alarm is output together with alarm 27010 "Tolerance for safe operational stop exceeded" or after alarm 27001 "STOP F triggered".
The alarm can be reprogrammed in MD ALARM_REACTION_CHAN_NOREADY (channel not ready).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Trigger a "Deceleration on the current limit" and activation of the timer for a switchover after STOP A (see MD $MA_SAFE_PULSE_DISABLE_DELAY).
Eliminate causes of alarm "Tolerance for safe standstill exceeded" or "STOP F triggered" (see description of these alarms).
Switch control OFF - ON.