26050

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

1-1167

Axis %1 parameter set change from %2 to %3 not possible

%1 = Axis name, spindle number %2 = Index: current parameter block %3 = Index: new parameter block

The parameter block change cannot be performed without jumps. This is due to the content of the parameter block to be switched on, e.g. different load gear factors.

-    The NC switches to follow-up mode.

-    Local alarm reaction.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

In following cases, the parameter block change is carried out via MD 31060 and MD 31050 without an alarm, even with different load gear ratio settings:

1.    In speed-controlled and follow-up mode.

2.    With position control with the direct encoder.

3.    With position control with the indirect encoder only within the position window (MD 36500 > actual position > MD 36500).

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved