Axis %1 encoder %2 measurement not possible with this controller module

%1 = NC axis number %2 = Encoder number

If the MD $MN_DRIVE_DIAGNOSIS[8] contains a value not equal to zero, then the control has found at least one control module which does not support measuring. Measuring was programmed from the part program for the associated axis.

-    Local alarm reaction.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

If possible, modify the measuring motion such that the axis concerned does not have to travel; do not program this axis in the MEAS block again. However, it is then no longer possible to query a measured value for this axis. Otherwise, exchange the controller module for one that supports measuring. See MD $MN_DRIVE_DIAGNOSIS[8].

Clear alarm with the RESET key. Restart part program