26014 |
Axis %1 machine data %2 invalid value |
Parameters: |
%1 = Axis name, spindle number %2 = String: MD identifier |
Definitions: Reactions: |
Machine data includes a value that is not valid. - NC not ready. - The NC switches to follow-up mode. - Mode group not ready, also effective for single axes - NC Start disable in this channel. |
Remedy: Program Continuation: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. Repeat entry with correct value and then Power On. Switch control OFF - ON. |
© Siemens AG 2005 All Rights Reserved