26009

Axis %1 QEC: memory overflow

Parameters:

Definitions:

%1 = Axis name, spindle number

The product of the data $AA_QEC_COARSE_STEPS+1 and $AA_QEC_FINE_STEPS must not exceed the maximum number of the characteristic curve points (MD 18342

MM QEC MAX POINTS). With a direction-dependent characteristic, this criterion applies to 2 * ($AA_QEC_COARSE_STEPS+1) * $AA_QEC_FINE_STEPS!

Reactions:

Remedy:

- Alarm display.

Please inform the authorized personnel/service department. Either increase 18342

MM QEC MAX POINTS or reduce $AA QEC COARSE STEPS and/or $AA_QEC_FINE_STEPS.

Program Continuation:

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-1150