Remedy:
Program Continuation:
Axis %1 encoder %2 parameterization error: grid point distance with linear encoders
%1 = Axis name, spindle number %2 = Encoder number
The encoder grid point distance set in the axis-specific MD 31010 ENC_GRID_POINT_DIST is zero.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Please inform the authorized personnel/service department. Enter the encoder grid point distance according to the data given by the machine (or measuring device) manufacturer in the machine data 31010 ENC_GRID_POINT_DIST.
Switch control OFF - ON.
© Siemens AG 2005 All Rights Reserved