Reactions:
Remedy:
Program Continuation:
Axis %1 drive fault
%1 = Axis name, spindle number
The drive signals a serious fault of status class 1 (ZK1). The exact cause of the fault can be recognized by evaluating the following drive alarms which are output in addition:
Alarm 300 500, alarms 300 502 - 300 505, alarm 300 508, alarm 300 515, alarm 300 608, alarm 300 612, alarm 300 614, alarms 300 701 - 300 761, alarm 300 799.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Evaluation of the drive alarms listed above.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
© Siemens AG 2005 All Rights Reserved