25200

Parameters:

Definitions:

Reactions:

Remedy:


Program Continuation:


Axis %1 requested set of parameters invalid

%1 = Axis name, spindle number

A new parameter set has been requested for the positioning control. The number of this parameter set is beyond the permissible limit (8 parameter sets: 0 ... 7 available).

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Check the axis-specific/ spindle-specific interface signals (DB 31 - 48, DBX 9.0, 9.1 and 9.2 "Select parameter set servo A, B, C").

One parameter set includes the following machine data:

Modify MD 31050: DRIVE_AX_RATIO_DENOM [n]

Modify MD 31060: DRIVE_AX_RATIO_NUMERA [n]

Modify MD 32200: POSCTRL_GAIN [n]

Modify MD 32800: EQUIV_CURRCTRL_TIME [n]

Modify MD 32810: EQUIV_SPEEDCTRL_TIME [n]

Modify MD 32910: DYN_MATCH_TIME [n]

Modify MD 36200: AX_VELO_LIMIT [n]

Clear alarm with the RESET key. Restart part program


© Siemens AG 2005 All Rights Reserved


1-1138