25010

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 pollution of measuring system

%1 = Axis name, spindle number

The encoder used for position control sends a contamination signal (only in measuring systems with contamination signal).

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Axes of this channel must be re-referenced.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. Check the measuring system in accordance with the instructions given by the measuring device manufacturer.

Clear alarm with the RESET key in all channels of this mode group. Restart part program.


© Siemens AG 2005 All Rights Reserved


1-1122