25000

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 hardware fault of active encoder

%1 = Axis name, spindle number

The signals of the currently active position actual value encoder (interface signal DB 31 -48, DBX 1.5 = 1 or DBX 1.6 = 1) are missing, do not have the same phase, or exhibit grounding/short-circuit.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Axes of this channel must be re-referenced.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. Check measuring circuit connectors for correct contacting. Check encoder signals and replace the encoder if faults are found.

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved


1-1120