Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 block %3 spindle %2 chuck speed exceeded
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
The actual spindle speed is higher than the maximum speed configured in machine data 35100 $MA_SPIND_VELO_LIMIT plus a tolerance of 10 percent (fixed setting).
The alarm should not occur after correct optimization of the drive actuator and gear configuration.
This alarm can be reconfigured with MD 11412
$MN_ALARM_REACTION_CHAN_NOREADY (channel not ready to operate) to 'BAG not ready'.
Note: Reconfiguring affects all alarms with alarm response 'Chan not ready'.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Please inform the authorized personnel/service department. Check the setup and optimization data of the drive actuator in accordance with the Installation and Start-up Guide and make corrections.
Increase the tolerance window in machine data 35150 SPIND_DES_VELO_TOL.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
© Siemens AG 2005 All Rights Reserved