22100

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 block %3 spindle %2 chuck speed exceeded

%1 = Channel number

%2 = Axis name, spindle number

%3 = Block number, label

The actual spindle speed is higher than the maximum speed configured in machine data 35100 $MA_SPIND_VELO_LIMIT plus a tolerance of 10 percent (fixed setting).

The alarm should not occur after correct optimization of the drive actuator and gear configuration.

This alarm can be reconfigured with MD 11412

$MN_ALARM_REACTION_CHAN_NOREADY (channel not ready to operate) to 'BAG not ready'.

Note: Reconfiguring affects all alarms with alarm response 'Chan not ready'.

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. Check the setup and optimization data of the drive actuator in accordance with the Installation and Start-up Guide and make corrections.

Increase the tolerance window in machine data 35150 SPIND_DES_VELO_TOL.

Clear alarm with the RESET key in all channels of this mode group. Restart part program.


1-1107


© Siemens AG 2005 All Rights Reserved