22062

Channel %1 axis %2 reference point approach: zero marker search velocity (MD) is not reached

Parameters:

%1 = Channel number

Definitions:

Reactions:

%2 = Axis name, spindle number

The configured zero marker search velocity is not reached.

- NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Check active spindle speed limitations. Configure a lower zero marker search velocity

$MA_REFP_VELO_SEARCH_MARKER. Check the tolerance range for the actual velocity $MA SPIND DES VELO TOL. Set a different referencing mode $MA_ENC_REFP_MODE != 7.

Program Continuation:

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-1098