22013
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 block %2 dependent spindle %3 is in simulation.
%1 = Channel number %2 = Block number, label %3 = Following spindle number
When coupling, no synchronism can be achieved if the following spindle/axis is in simulation mode and the lead spindle/axis is not.
- Alarm display.
Set the lead spindle/axis to simulation mode, or do not simulate the following spindle/axis ($MA_CTRLOUT_TYPE). If the differing settings have been selected on purpose, the alarm can be suppressed with the machine data 11410 SUPPRESS_ALARM_MASK Bit21 = 1.
Clear alarm with the Delete key or NC START.
1-1076