22011

Parameters:


Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 block %3 spindle %2 change to programmed gear stage not possible

%1 = Channel number %2 = Spindle number %3 = Block number, label

With the 'DryRun', 'ProgramTest' and 'SearchRunByProgTest' functions deselected, it is not possible in the Repos module to carry out a gear stage change to a previously programmed gear stage. This is the case, if the spindle is in the deselection block not active in speed control mode, as a slave axis or in a transformation. Execution of a gear stage change is avoided if the above mentioned functions are deselected by resetting bit 2 of machine data 35035 SPIND_FUNCTION_MASK.

- Alarm display.

Change deselection block or block search target block to speed control mode (M3, M4, M5, SBCOF). Set bit 2 of machine data 35035 SPIND_FUNCTION_MASK to 0.

Clear alarm with the Delete key or NC START.


© Siemens AG 2005 All Rights Reserved


1-1074