21800

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 workpiece setpoint %2 reached

%1 = Channel number %2 = Workpiece setpoint

This alarm is activated via MD 27880 PART_COUNTER, bit 1:

The number of counted workpieces ($AC_ACTUAL_PARTS or $AC_SPECIAL_PARTS) is equal or already larger than the programmed value for the number of required workpieces ($AC_REQUIRED_PARTS).

At the same time, the channel VDI signal "Workpiece setpoint reached" is output.

The value for the number of the counted workpieces ($AC_ACTUAL_PARTS) is reset while the value of $AC_SPECIAL_PARTS remains.

-    NC not ready.

-    Interface signals are set.

-    Alarm display.

No program interrupt. Delete alarm display.

Clear alarm with the Delete key or NC START.


1-1071


© Siemens AG 2005 All Rights Reserved