Channel %1 block %3 axis %2 touch probe already deflected, edge polarity not possible

%1 = Channel number

%2 = Axis name, spindle number

%3 = Block number

The probe programmed under the keyword MEAS or MEAW is already deflected and has switched. For a further measuring operation, the probe signal must first be canceled (quiescent state of the probe).

The axis display is of no significance at the present time but an axis-specific evaluation has been planned for later stages of development.

-    Local alarm reaction.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Verify the start position of the measuring operation or check the probe signals in the PLC interface (DB10.DBB107). Are the cables and connectors in good order?

Clear alarm with the RESET key. Restart part program