20140

Channel %1 motion synchronous action: traversing of command axis %2 see NC alarm %3

Parameters:

%1 = Channel number

%2 = Axis

%3 = NC alarm

Definitions:

An NC alarm was detected for a command axis which is to be traversed from a synchronous action. The NC alarm is indicated by an MMC alarm number in the 3rd parameter.

Reactions:

- NC Start disable in this channel.

Remedy:

Program Continuation:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

See help information for the additional alarms.

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-1028