20130

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 contour tunnel monitoring

%1 = Channel number

The tool tip has exited the tunnel placed around the desired contour, i.e. the distance between tool tip and desired contour was greater than specified in the MD 21050 CONTOUR_TUNNEL_TOL.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. Check the following points in turn:

1.    Is the machine in working order? That is, has the alarm been tripped by a sluggish axis, tool breakage or collision?

2.    If the machine is in working order, reduce the velocity or improve the controller setting.

3.    Possibly increase the size of the tunnel and monitor errors via analog output in order to ascertain the cause.

Clear alarm with the RESET key in all channels of this mode group. Restart part program.


© Siemens AG 2005 All Rights Reserved


1-1026