20105 |
Channel %1: axes stopped by digitizer. Error code: %2 |
Parameters: |
%1 = Channel number |
Definitions: |
%2 = Error code of digitizing unit The digitizing unit has recognized an error in the communication and signaled this to the NC. |
Reactions: |
- Channel not ready. - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. Please inform the authorized personnel/service department. Error code 1: Check cable connection leading to the digitizing unit. Other error codes: See manual for digitizing unit. |
Program Continuation: |
Clear alarm with the RESET key. Restart part program |
© Siemens AG 2005 All Rights Reserved