20100

Channel %1: invalid configuration for digitizing

Parameters:

Definitions:

%1 = Channel number

The digitizing function expects the definition of three geometry axes in the channel.

At the available baud rate for a transmission of the actual positions and setpoint velocities between the NC and the digitizing device, the interpolation cycle must be set to a minimum of 5ms.

Reactions:

-    Interface signals are set.

-    Alarm display.

Remedy:

Please inform authorized personnel / the service department.

Define three geometry axes for the digitizing channel by means of machine data.

Use an interpolation cycle greater than 5ms.

Program Continuation:

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved