20094

Axis %1 function has been aborted

Parameters:

Definitions:

%1 = Axis name, spindle number

The function has been aborted. The possible reasons for this are:

Because a pulse disable has occurred, the torque can no longer be provided.

The PLC has removed the acknowledgments.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

Reactions:

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Check whether

there is a pulse disable from the infeed/regenerative-feedback unit or from the PLC? the acknowledgement bits have been deleted by the PLC even though NCK has not requested deselection?

Program Continuation:

Clear alarm with the RESET key in all channels of this mode group. Restart part program.

© Siemens AG 2005 All Rights Reserved

1-1008