Axis %1 standstill monitoring at fixed-stop end point has been triggered

%1 = Axis name, spindle number

The position of the axis has been beyond the zero speed window ever since selection has been completed.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department.

Check the mechanical components, e.g. has the stop broken away? Has the part to be clamped given way?

Position window for zero speed control too small (37020 MD: $MA_FIXED_STOP_WINDOW_DEF) (43520 setting data: $SA_FIXED_STOP_WINDOW). Default is 1 mm in each case.

Clear alarm with the RESET key in all channels of this mode group. Restart part program.