20072

Parameters:

Definitions:


Reactions:

Remedy:


Program Continuation:


Channel %1 axis %2 is not an indexing axis

%1 = Channel number %2 = Axis number

The displayed axis is operated as a concurrent positioning axis. Its target position is parameterized in the FC INDEX-AXIS as indexing position number, but the axis is not an indexing axis.

- Alarm display.

Please inform the authorized personnel/service department. The FC POS-AXIS for linear and rotary axes should be used or the axis should be declared as an indexing axis. Corresponding machine data for indexing axis declaration:

Modify MD 30500: INDEX_AX_ASSIGN_POS_TAB Modify MD 10900: INDEX_AX_LENGTH_POS_TAB_1 Modify MD 10910: IN DEX_AX_POS_TAB_1 Modify MD 10920: INDEX_AX_LENGTH_POS_TAB_2 Modify MD 10930: IN DEX_AX_POS_TAB_2

Alarm display showing cause of alarm disappears. No further operator action necessary.


1-993


© Siemens AG 2005 All Rights Reserved