20071

Parameters:


Definitions:

Reactions:

Remedy:


Program Continuation:


Channel %1 axis %2 working area limit %3

%1 = Channel number %2 = Axis number %3 = "+" or "-"

The displayed axis is operated as a "concurrent positioning axis" and the corresponding working area limitation active for the axis is violated. No traversing movement.

With an additional message to alarm 20140, the axis is traversed as a command axis.

- Alarm display.

Specify smaller target position.

Deactivate working area limitation.

Set working area limitation differently.

Retract axis with JOG.

Alarm display showing cause of alarm disappears. No further operator action necessary.