20005

Parameters:

Definitions:

Reactions:

Remedy:


Program Continuation:


Channel %1 axis %2 reference point approach aborted

%1 = Channel number

%2 = Axis name, spindle number

Referencing could not be completed for all stated axes (e.g., abort caused by missing servo enable, measuring system switchover, release of direction key, etc.).

In distance-coded measuring systems, the alarm will also be displayed, if value 1 has been set in MD 34000 REFP_CAM_IS_ACTIV (reference cams) and one of the conditions indicated under remedy has been fulfilled.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Check the possible reasons for termination:

Servo enable missing (DB 31 - 48, DBX 2.1)

Measuring system switchover (DB 31 - 48, DBX 1.5 and DBX 1.6)

Traversing key + or - missing (DB 31 - 48, DBX 4.6 and DBX 4.7)

Feed override = 0 The feed disable is active

The axis-specific MD 34110 REFP_CYCLE_NR determines which axes are involved in the channel-specific referencing.

-1: No channel-specific referencing, NC Start without referencing.

0: No channel-specific referencing, NC Start with referencing.

1-8: Channel-specific referencing. The number entered here corresponds to the referencing sequence. (When all axes with contents 1 have reached the reference point, then the axes with contents 2 start, etc.).

Clear alarm with the RESET key. Restart part program


© Siemens AG 2005 All Rights Reserved


1-972