Program Continuation:
Channel %1 axis %2 reference point approach aborted
%1 = Channel number
%2 = Axis name, spindle number
Referencing could not be completed for all stated axes (e.g., abort caused by missing servo enable, measuring system switchover, release of direction key, etc.).
In distance-coded measuring systems, the alarm will also be displayed, if value 1 has been set in MD 34000 REFP_CAM_IS_ACTIV (reference cams) and one of the conditions indicated under remedy has been fulfilled.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Check the possible reasons for termination:
Servo enable missing (DB 31 - 48, DBX 2.1)
Measuring system switchover (DB 31 - 48, DBX 1.5 and DBX 1.6)
Traversing key + or - missing (DB 31 - 48, DBX 4.6 and DBX 4.7)
Feed override = 0 The feed disable is active
The axis-specific MD 34110 REFP_CYCLE_NR determines which axes are involved in the channel-specific referencing.
-1: No channel-specific referencing, NC Start without referencing.
0: No channel-specific referencing, NC Start with referencing.
1-8: Channel-specific referencing. The number entered here corresponds to the referencing sequence. (When all axes with contents 1 have reached the reference point, then the axes with contents 2 start, etc.).
Clear alarm with the RESET key. Restart part program