20003 |
Channel %1 axis %2 measuring system error |
Parameters: |
%1 = Channel number |
Definitions: |
%2 = Axis name, spindle number In a measuring system with distance-coded reference marks, the distance between two adjacent markers has been found to be more than twice the distance entered in the machine data 34300 ENC_REFP_MARKER_DIST. |
Reactions: |
The control issues the alarm after having made a second attempt in reverse direction with half the traversing velocity and detecting that the distance is too large again. - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. Determine the distance between 2 odd reference point markers (reference point marker interval). This value (which is 20.00 mm on Heidenhain scales) must be entered in the machine data 34300 ENC_REFP_MARKER_DIST. |
Program Continuation: |
Check the reference point track of the scale including the electronics for the evaluation. Clear alarm with the RESET key. Restart part program |
© Siemens AG 2005 All Rights Reserved