18202

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 block %2 curve table: instruction CTABEND without CTABDEF not allowed

%1 = Channel number %2 = Block number, label

The CTABEND instruction, which is used to terminate the definition, has been programmed in the program without starting a curve table definition with CTABDEF, or the CTABDEF and CTABEND instructions were not programmed in the same program level.

-    Interpreter stop

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

Remove the CTABEND command or add the CTABDEF( ..) command at the appropriate program location. The CTABDEF and CTABEND instructions must be programmed in the same program level (main or subprogram). Start the program again.

Clear alarm with the RESET key. Restart part program

1-957

© Siemens AG 2005 All Rights Reserved