18004

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 block %2 orientation of workpiece-related protection zone %3 does not correspond to the orientation of tool-related protection zone %4

%1 = Channel number %2 = Block number, label

%3 = Number of workpiece-related protection zone

The orientation of the workpiece-related protection zone and the orientation of the tool-related protection zone differ. If the protection zone number is negative, then this is a global protection zone.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Modify the protection zone definition or do not simultaneously activate protection zones that have different orientations.

Check machine data and modify the protection zone definition if necessary.

Clear alarm with NC START or RESET key and continue the program.


1-949


© Siemens AG 2005 All Rights Reserved