17600

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 block %2 preset on transformed axis %3 not possible

%1 = Channel number

%2 = Block number, label

%3 = Axis name, spindle number

The displayed axis is involved in the current transformation. This means that is it not possible to set the actual value memory (preset) for this axis.

Example:

Machine axis A should be set to the new actual value A 100 at the absolute position A 300.

N100 G90 G00 A=300 N101 PRESETON A=100

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Avoid preset actual value memory for axes which are participating in a transformation or deselect the transformation with the keyword TRAFOOF.

Clear alarm with NC START or RESET key and continue the program.


1-935