17502

Parameters:


Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 block %2 indexing axis %3 with Hirth tooth system stop is delayed

%1 = Channel number %2 = Block number, label %3 = Axis name

For the indexing axis, the 'Hirth tooth system' function is activated and the override has been set to 0 or another stop condition (e.g. VDI interface signal) is active. Since it is possible to stop only on indexing axes, the next possible indexing position is approached. The alarm is displayed until this position is reached or the stop condition is deactivated.

- Alarm display.

Wait until the next possible indexing position is reached or set override > 0 or deactivate another stop condition.

Alarm display showing cause of alarm disappears. No further operator action necessary.


© Siemens AG 2005 All Rights Reserved