Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 block %2 indexing axis %3 with Hirth tool system is active
%1 = Channel number %2 = Block number, label %3 = Axis name
The 'Hirth tooth system' function is activated for the indexing axis. This axis can therefore approach only indexing positions, another travel movement of the axis is not possible.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department.
Correct part program.
Correct FC16 or FC18 call.
Deselect machine data $MA_HIRTH_IS_ACTIVE.
Clear alarm with the RESET key. Restart part program
© Siemens AG 2005 All Rights Reserved