17190

Parameters:

Definitions:

Reactions:

Remedy:


Program Continuation:


Channel %1 block %2 illegal T number

%1 = Channel number %2 = Block number, label

In the displayed block, access is made to a tool that is not defined and therefore not available. The tool has been named by its T number, its name or its name and duplo number.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Check tool call in the NC part program:

Correct tool number T.. programmed?

Tool parameters P1 - P25 defined? The dimensions of the tool edge must have been entered previously either through the operator panel or through the V.24 interface. Description of the system variables $P_DP x [n, m] n ... Associated tool number T m ... Tool edge number D x ... Parameter number P

Clear alarm with NC START or RESET key and continue the program.


1-911