Program Continuation:
Channel %1 block %2 illegal T number
%1 = Channel number %2 = Block number, label
In the displayed block, access is made to a tool that is not defined and therefore not available. The tool has been named by its T number, its name or its name and duplo number.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Check tool call in the NC part program:
Correct tool number T.. programmed?
Tool parameters P1 - P25 defined? The dimensions of the tool edge must have been entered previously either through the operator panel or through the V.24 interface. Description of the system variables $P_DP x [n, m] n ... Associated tool number T m ... Tool edge number D x ... Parameter number P
Clear alarm with NC START or RESET key and continue the program.
© Siemens AG 2005 All Rights Reserved