17140

Channel %1 block %2 NCK output %3 is assigned to a function via machine data

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

%3 = No. of output

The programmed digital/analog output is assigned to an NC function (e.g. software cams).

Reactions:

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Remedy:

Please inform the authorized personnel/service department. Use another output or deactivate concurrent NC function via MD.

Program Continuation:

Clear alarm with NC START or RESET key and continue the program.


1-901