17140 |
Channel %1 block %2 NCK output %3 is assigned to a function via machine data |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
%3 = No. of output The programmed digital/analog output is assigned to an NC function (e.g. software cams). |
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. |
Remedy: |
Please inform the authorized personnel/service department. Use another output or deactivate concurrent NC function via MD. |
Program Continuation: |
Clear alarm with NC START or RESET key and continue the program. |
© Siemens AG 2005 All Rights Reserved