16948

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 dependent channel %2 still active

%1 = Channel ID %2 = Channel ID

This alarm is active with "Group Serupro" only. _Group Serupro" is activated by means of "$MC_SERUPRO_MODE BIT2" and enables the retrace support of entire channel groups during block search.

A _dependent channel_ is a channel that had indirectly been started by the currently active channel. The currently active channel was started via PLC.

This channel m_u_s_t be terminated (i.e. reached M30) before the current channel is terminated.

This alarm occurs if the currently active channel is terminated before the dependent channel.

- Alarm display.

Switch off "Group Serupro" (see $MC_SERUPRO_MODE) or install WAITE.

Clear alarm with the Delete key or NC START.


© Siemens AG 2005 All Rights Reserved


1-872